What was found
DURING SCHEDULED S6 INSPECTION PER CARD S6-54104, FOUND BS 1130 FRAME SHEAR TIE CORRODED AT STR 29L. REPLACED SHEAR TIE PER SRM 53-10-4. M-54 NR 278.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED S6 INSPECTION PER CARD S6-54104, FOUND BS 1130 FRAME SHEAR TIE CORRODED AT STR 29L. REPLACED SHEAR TIE PER SRM 53-10-4. M-54 NR 278.