What was found
DURING SCHEDULED S6 INSPECTION PER CARD S6-54104, FOUND BS 1030 FRAME UPPER FLANGE DENTED ABOVE STR 29L AT U-CHANNEL ATTACHMENT. REPAIRED PER SRM 51-40-3 AND 51-20-04. M-54 NR 384.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED S6 INSPECTION PER CARD S6-54104, FOUND BS 1030 FRAME UPPER FLANGE DENTED ABOVE STR 29L AT U-CHANNEL ATTACHMENT. REPAIRED PER SRM 51-40-3 AND 51-20-04. M-54 NR 384.