What was found
DURING SCHEDULED NR 1 CHECK, FOUND CORROSION ON TRANVERSE FLOORBEAM AT TOP FLANGE FS 309 LBL 29 - LBL 50. REPLACED TRANVERSE FLOORBEAM PER SRM 51-2-1, M-54 NR 59.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED NR 1 CHECK, FOUND CORROSION ON TRANVERSE FLOORBEAM AT TOP FLANGE FS 309 LBL 29 - LBL 50. REPLACED TRANVERSE FLOORBEAM PER SRM 51-2-1, M-54 NR 59.