DURING SCHEDULED NR 1 CHECK, FOUND CORROSION ON TRANVERSE FLOORBEAM FS 333 LBL 55, BETWEEN REPAIR AND TOP FLANGE. REPLACED FLOORBEAM AS PER SRM 51-2-1 M-54 NR 260.