What was found
DURING PERFORMANCE OF 3 YEAR CPCP INSPECTION PER CARD S3-54102, FOUND CORROSION ON FWD FACE OF CIRCUMFERENTIAL BS 990 INBD OF STRINGER 29R AT FUSELAGE ATTACH RIVETS. REPAIRED PER SRM 53-10-4 FIG 11, SHEET 2 AND 3. (Z)