What was found
5592-STL- ELEC SMOKE ANNUNCIATOR ILLUMINATED. MAINTENANCE TROUBLESHOT AND DEFERRED THE NR 2 BLEED SYSTEM. MAINTENANCE GROUND RAN RT BLEED AND PACK, OPS CHECK OK IAW MM 36-11-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
5592-STL- ELEC SMOKE ANNUNCIATOR ILLUMINATED. MAINTENANCE TROUBLESHOT AND DEFERRED THE NR 2 BLEED SYSTEM. MAINTENANCE GROUND RAN RT BLEED AND PACK, OPS CHECK OK IAW MM 36-11-00.