What was found
GUST LOCK WILL NOT DISENGAGE. MAINTENANCE DEFERRED SYSTEM IAW MEL. SUBSEQUENTLY CLEARED DMI BY REMOVING AND REPLACING THE RUDDER GUST LOCK SOLENOID.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GUST LOCK WILL NOT DISENGAGE. MAINTENANCE DEFERRED SYSTEM IAW MEL. SUBSEQUENTLY CLEARED DMI BY REMOVING AND REPLACING THE RUDDER GUST LOCK SOLENOID.