What was found
FLT 5468 - STL - BLEED NR 1 & 2 LEAK MESSAGE ON THE EICAS FOLLOWED BY A BURNING SMELL IN THE COCKPIT. MAINTENANCE REMOVED AND REPLACED THE O-RINGS AND CLAMP ON THE BLEED DUCT FOLLOWED BY SUCCESSFUL OPERATION OF THE BLEED AIR SYSTEM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLT 5468 - STL - BLEED NR 1 & 2 LEAK MESSAGE ON THE EICAS FOLLOWED BY A BURNING SMELL IN THE COCKPIT. MAINTENANCE REMOVED AND REPLACED THE O-RINGS AND CLAMP ON THE BLEED DUCT FOLLOWED BY SUCCESSFUL OPERATION OF THE BLEED AIR SYSTEM.