What was found
DURING CLIMB THE AIRCRAFT WOULD NOT PRESSURIZE. AIRCRAFT RETURNED TO STL. MAINTENANCE INSPECTED AND REPLACED THE PNEUMATIC OUTFLOW VALVE. SYSTEM OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CLIMB THE AIRCRAFT WOULD NOT PRESSURIZE. AIRCRAFT RETURNED TO STL. MAINTENANCE INSPECTED AND REPLACED THE PNEUMATIC OUTFLOW VALVE. SYSTEM OPS CHECKED GOOD.