ELECTRICAL SMOKE ODOR WITH VISIBLE SMOKE FROM F/O'S OTBD FLOORBOARD AREA, PLANE MADE AN UNSCHEDULED LANDING. MAINTENANCE INSPECTED AND FOUND NR 1 AIR CYCLE MACHINE LOCKED UP, REPLACED NR 1 AIR CYCLE MACHINE AND OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ELECTRICAL SMOKE ODOR WITH VISIBLE SMOKE FROM F/O'S OTBD FLOORBOARD AREA, PLANE MADE AN UNSCHEDULED LANDING. MAINTENANCE INSPECTED AND FOUND NR 1 AIR CYCLE MACHINE LOCKED UP, REPLACED NR 1 AIR CYCLE MACHINE AND OPS CHECKED GOOD.