Service difficulty report · Indication Sys · Emb EMB145XR

Difficulty date
January 30, 2018
Submitted
February 1, 2018
Operation
Air carrier
Aircraft
N17138
Make and model
Emb EMB145XR
Aircraft serial
145727
Aircraft time
39,494 hours, 23,734 cycles
Part
Indication Sys
Condition
Malfunctioned
Location
Anti Ice System
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF, ENCOUNTERED ICING AND ECS BLEED TEMP CARROT NR 1 WENT INTO THE RED BAND. RECEIVED A BLEED 1 OVERTEMP MESSAGE. IAW QRH ISOLATED THAT SIDE AND CONTINUED AT FL 240 OUT OF ICING CONDITIONS. ENCOUNTERED ICING AGAIN AND RECEIVED A BLEED 2 OVERTEMP. BEFORE RUNNING QRH, RECEIVED A W/G A/ICE FAIL AND THEN AN ICE CONDA/I INOP MESSAGE. BEFORE CLOSING BLEED 2, LOST CABIN PRESSURIZATION AND THE PRESSURE CLIMBED ABOVE 10,000. DESCENDED QUICKLY TO PREVENT MASKS DROPPING. RAN AIR BLEED SYSTEM TEST AND ANTI ICE TEST. FOUND THE NR 1 BLEED CARROT TO MOVE MULTIPLE TIMES OVER FROM GREEN TO RED BACK TO GREEN. FAIL NEVER RECORDED OR SHOWN ON EICAS. AFTER USING FIM AND CONFERING WITH PREVIOUS HISTORY, INSPECTED THERMOSTATS IN THE CARGO BAY, FOUND THE THERMOSTATS TO BE IN GOOD CONDITION. PULLED PYLON PANELS FOR L & R, NO DEFECTS NOTED. CHANGED THE FAN AIR VALVE DUE TO FIM ON LOG PAGE 358705. PERFORMED AN OPS TEST OF AIR BLEED SYSTEM AND FOUND THE BLEED 1 CARROT STAYED IN GREEN. DURING TESTING SECTION. BLEED 1 & 2 OPS TEST AND LEAK TESTED GOOD FROM CARGO BAY TO PYLON PANELS.