What was found
FLOOR SUPPORT HAS CORROSION BETWEEN RT FLOOR SILL & RT OMEGA BEAM AT FR 61. BLENDED CORROSION ON PROFILE T RT FLOOR SUPPORT, WAS FOUND TO BE OUT OF LIMITS. MATERIAL REMOVED .026, REMOVED PROFILE T. INSTALLED PROFILE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT HAS CORROSION BETWEEN RT FLOOR SILL & RT OMEGA BEAM AT FR 61. BLENDED CORROSION ON PROFILE T RT FLOOR SUPPORT, WAS FOUND TO BE OUT OF LIMITS. MATERIAL REMOVED .026, REMOVED PROFILE T. INSTALLED PROFILE.