What was found
APU FIREWALL IS CRACKED @ RT SIDE @ 2:00 O'CLOCK POSITION- FOUND SMALL CRACK IN RT APU FIREWALL AREA AND STOP DRILLED CRACK. FABRICATED DOUBLER TO BE INSTALLED OVER STOP DRILLED CRACK ON APU, INSTALLED DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU FIREWALL IS CRACKED @ RT SIDE @ 2:00 O'CLOCK POSITION- FOUND SMALL CRACK IN RT APU FIREWALL AREA AND STOP DRILLED CRACK. FABRICATED DOUBLER TO BE INSTALLED OVER STOP DRILLED CRACK ON APU, INSTALLED DOUBLER.