What was found
LT OMEGA BEAM UPPER DIGITAL SUPPORT HAS CORROSION AROUND NUTPLATE HOLE AT FR 61. BLENDED DAMAGED AREA ON LT GUSSET AT FR 61 FOUND TO BE WITH IN LIMITS REMAINING THICKNESS .057" REQUIRES NDI. PERFORMED HFEC INSPECTION OF BLENDED AREA CRACK FOUND. REMOVED LT OMEGA BEAM UPPER DIGITAL SUPPORT, INSTALLED NEW LT OMEGA BEAM UPPER DIGITAL SUPPORT AT FR 61. REMOVED DAMAGED AND INSTALLED NEW LT OMEGA BEAM UPPER DIGITAL SUPPORT AT FR 61.