What was found
RT FWD BAGGAGE FLOOR SILL HAS 5 EA CORRODED NUTPLATE LOCATIONS BETWEEN FR.61-65. REMOVED RT FLOOR SILL AT FR 61-65. INSTALLED RT FLOOR SILL STILL NEEDS NUTPLATES INSTALLED. INSTALLED NUTPLATES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT FWD BAGGAGE FLOOR SILL HAS 5 EA CORRODED NUTPLATE LOCATIONS BETWEEN FR.61-65. REMOVED RT FLOOR SILL AT FR 61-65. INSTALLED RT FLOOR SILL STILL NEEDS NUTPLATES INSTALLED. INSTALLED NUTPLATES.