As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
F/A SMELLS BURNING PLASTIC. NO SMOKE, NO FIRE, PAX REPORTED BURING WIRING SMELL. NO ODOR DETECTED ON ARRIVAL. INSPECTED GALLEY. FOUND NO BURNT OR DAMAGED COMPONENTS. #1 COFFEE BREWER WAS FOUND UNLATCHED AND UNSEATED. THE CONTACTS SMELLED OF ELECTRICAL ARCING. FOUND THAT BREWER #1 COULD NOT LATCH. CLEARED DEBRIS FROM THE DETENT HOLE IN THE BREWER TRACK. LATCHED AND SECURED. OPS CHECK GOOD.