Service difficulty report · Sensor · Emb EMB145XR

Difficulty date
November 26, 2019
Submitted
December 10, 2019
Operation
Air carrier
Aircraft
N13123
Make and model
Emb EMB145XR
Aircraft serial
145688
Aircraft time
43,312 hours, 26,508 cycles
Engine
Rroyce AE3007A1E
Part
Sensor
Part number
23073715
Part serial
6479V
Condition
Failed
Location
Oil Temp
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
E

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

E2 HI OIL TEMP ON FINAL APPROACH, E2 TEMP SHOT TO 218C, CREW REDUCED TLA'S TO IDLE AND TEMP WENT INTO GREEN RANGE. ON 2ND ATTEMPT E2 OIL TEMP OIL TEMP WENT IMMEDIATELY INTO RED BAND AND DID NOT COME DOWN WHEN TLA'S REDUCED TO IDLE. POST 1 MINUTE CREW SHUT DOWN E2 AND LANDED WITH ONE ENG. ALL OTHER ENG PARAMETERS NORMAL INDICATIONS--- SWAPPED OIL TEMP SENSORS SIDE TO SIDE, #2 OPS CHECKED GOOD, SO THEN REPLACED #1 OIL TEMP SENSOR OPS CHECK GOOD