What was found
FOUND FLOOR BEAM 41 HAS CORROSION FROM STRINGER 17 TO 21. REMOVED AND REPLACED CORRODED SECTION OF BEAM PER SRM. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOOR BEAM 41 HAS CORROSION FROM STRINGER 17 TO 21. REMOVED AND REPLACED CORRODED SECTION OF BEAM PER SRM. (M)