What was found
OUTBOARD FLANGE AT FS 529.00 RBL 27.00 HAS MISS-DRILLED/ DOUBLE DRILLED HOLES THROUGH THE PRESSURE FLOOR AND FLOORBEAM FLANGE INBOARD FLANGE. THE HOLE IS 0.35" (EDGE TO EDGE ) X 0.2. COMPLIED WITH BSC EO 601R-53-19683.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OUTBOARD FLANGE AT FS 529.00 RBL 27.00 HAS MISS-DRILLED/ DOUBLE DRILLED HOLES THROUGH THE PRESSURE FLOOR AND FLOORBEAM FLANGE INBOARD FLANGE. THE HOLE IS 0.35" (EDGE TO EDGE ) X 0.2. COMPLIED WITH BSC EO 601R-53-19683.