What was found
FS 280.00 FWD FLOOR SUPPORT J-ANGLE IS CORRODED BETWEEN LBL 9 AND RBL 9. REMOVED AND REPLACED FS 280.00 FWD FLOOR SUPPORT J-ANGLE BETWEEN LBL 9 AND RBL 9 IAW CRJ 200 SRM 51-40-11 AND 51-42-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 280.00 FWD FLOOR SUPPORT J-ANGLE IS CORRODED BETWEEN LBL 9 AND RBL 9. REMOVED AND REPLACED FS 280.00 FWD FLOOR SUPPORT J-ANGLE BETWEEN LBL 9 AND RBL 9 IAW CRJ 200 SRM 51-40-11 AND 51-42-06.