What was found
DENT WAS FOUND ON THE FUSELAGE SKIN 0.75 INCH AFT OF FUSELAGE STATION X = 559 +80 BETWEEN STRINGERS S-15L AND S-16L. THE DAMAGE IS RECORDED AS 2.5 INCHES BY 2.0 INCHES WITH A MAXIMUM DEPTH OF 0.125 INCH. TEMPORARY DISPOSITION IAW STS ENGINEERING EA 5-2010-241. REPEAT INSPECTION EVERY 100 FH, FLY ON TO NEXT C CHECK NOT TO EXCEED 3300 FH WITHIN WHICH TIME ACCOMPLISH AN EXTERNAL NON-FLUSH PERMANENT REPAIR -PRESSURIZED AREA IN ACCORDANCE WITH SRM 53-00-31, FIGURE 1.