As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CREASED DENT AT LOWER CARGO DOOR OPENING WAS FOUND MEASURING 5.6" X 1.75" W X 0.081 DEEP BETWEEN FRAMES 589 -605 STR 18-19L. PERFORMED A MAJOR REPAIR TO DAMAGED FUSELAGE SKIN BETWEEN FS 589-605 STR 17-19L IAW BOMBARDIER SERVICES CORPORATION ENGINEERING ORDER NO: 601R-53-20038.