What was found
GROUND SPOILERS DEPLOY ADVISORY POSTED ON TAKEOFF AT THROTTLE UP. REMOVED NR 1 SECU; REMOVED NR 2 SECU. REMOVED AND REPLACED ASCU & OP CHECK GOOD IAW AMM 32-44-16. PARTS EFFECTIVITY VERIFIED. INSTALLED SERVICEABLE SECU IN NR 1 POSITION IAW AMM 27-61-04. OP'S CHECKED GOOD AT THIS TIME. VERIFIED PART EFFECTIVITY. INSTALLED SERVICEABLE SECU IN NR 2 POSITION IAW AMM 27-61-05-04 OP'S CHECKED GOOD AT THIS TIME VERIFIED PART EFFECTIVITY. SPOILER SYS INTERFACE WITH ASCU, THROTTLE CONTROL & RA SYS CHECKS GOOD IAW AMM 27-60-00. NO DEFECTS FOUND ON TAXI CHECK.