What was found
THE FLOORBEAM AT APPROXIMATELY FS 617 AND RBL 27 TO BE CORRODED AT A NUT PLATE. THE CORROSION WAS REMOVED BY BLENDING RESULTING IN A 1.08" X 0.54" X 0.027" DEEP BLEND. REPAIRED IAW EA CRJ253-00494 AND ASSOCIATED 8110-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THE FLOORBEAM AT APPROXIMATELY FS 617 AND RBL 27 TO BE CORRODED AT A NUT PLATE. THE CORROSION WAS REMOVED BY BLENDING RESULTING IN A 1.08" X 0.54" X 0.027" DEEP BLEND. REPAIRED IAW EA CRJ253-00494 AND ASSOCIATED 8110-3.