Service difficulty report · Transmitter · Cndair CL6002B19

Difficulty date
April 23, 2012
Submitted
April 26, 2012
Operation
Air carrier
Aircraft
N8560F
Make and model
Cndair CL6002B19
Aircraft serial
750
Aircraft time
23,892 hours, 20,667 cycles
Part
Transmitter
Condition
Faulty
Location
Te Flap
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SPLIT FLAP CONDITION. SELECTED FLAPS 8: LT FLAP DEPLOYED TO 8 DEG, RT FLAP DEPLOYED TO 2 DEG. RT FLAP POSITION SENSOR RIG CHECKS GOOD. BEGINNING OF THE NIGHT THE RT FLAP WAS 6 DEGREES HIGHER ON EACH FLAP DETENT. BEFORE DEFERRING FLAP POSITION SENSOR IT WAS ABOUT 15 DEGREES OFF AND FLAPS WEREN’T SKEWED OR TWISTED, JUST AN INDICATION PROBLEM. NEEDS NEW SENSOR PN: 601R93030-3. REMOVED AND REPLACED RT FLAP POSITION TRANSMITTER IAW AMM 27-55-01 OPC GOOD PLACARD REMOVED. THIS CLEARS DMX62469. OK FOR SVC.