What was found
FLOOR SUPPORT AFT OF SERVICE DOOR CORRODED. BLENDED CORROSION AND FOUND AREA TO BE WITHIN LIMITS WITH .004. REMOVED AND .046 REMAINING IAW SRM 53-00-00. RESTORED FINISH IAW SRM 51-21-11 AND 51-21-16.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT AFT OF SERVICE DOOR CORRODED. BLENDED CORROSION AND FOUND AREA TO BE WITHIN LIMITS WITH .004. REMOVED AND .046 REMAINING IAW SRM 53-00-00. RESTORED FINISH IAW SRM 51-21-11 AND 51-21-16.