What was found
DURING PMI FOUND EMERGENCY FLOOR TRACK LIGHTING INOPERABLE FROM ROWS 9-13. TROUBLESHOOT PER WM 33-51-00. REMOVED AND REPLACED NR 4 INVERTER IAW AMM 33-51-07. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING PMI FOUND EMERGENCY FLOOR TRACK LIGHTING INOPERABLE FROM ROWS 9-13. TROUBLESHOOT PER WM 33-51-00. REMOVED AND REPLACED NR 4 INVERTER IAW AMM 33-51-07. OPS CHECK GOOD.