What was found
DURING PMI FOUND EMERGENCY FLOOR TRACK LIGHTING FROM ROWS 5-8 INOPERABLE. REMOVED AND REPLACED EMERGENCY LIGHTING INVERTER IAW AMM 33-51-07. OPERATIONS CHECK GOOD. OK FOR SERVICE.