What was found
THE FOLLOWING EMERGENCY LIGHTS STAY ON AFTER POWER CUT: LEFT FWD O/W EXTERNAL, RIGHT AFT O/W EXTERNAL, ALL FOUR OW EXIT INTERNAL, BOTH AFT O/W FLOOR EXIT INTERNAL AND AFT FACING CENTER CEILING. REMOVED AND REPLACED NR 3 EMERGENCY LIGHT BATTERY CHARGER IAW CRJ 900 AMM 33+51-17-400-802. OPS TEST OF EMERGENCY POWER SUPPLY UNIT 3 GOOD IAW CRJ 900 AMM 33-51-17-710-801. P/N 11-0049, S/N OFF 23351, S/N ON 23187.