What was found
GEAR DISAGREE ON CLIMBOUT, QRH WAS COMPLETED. RT MAINS WERE RED WOULD NOT RETRACT COMPLETELY CYCLED IAW QRH RETRACTED COMPLETELY ON RECYCLE. FOUND RT MLG UPLOCK TARGET REQUIRED RESECURING & RIGGING. RESECURED & RIGGED RT MLG UPLOCK TARGET IAW CMM 32-30-15. OPS CHECK MLG RETRACTION SYS IAW AMM 32-30-00. OPS CHECK GOOD, COULD NOT DUPLICATE DISCREPENCY THROUGH 5 CY LANDING GEAR ACTUATION CYCLES. ACFT OK FOR SERVICE AMM 32-61-05.