What was found
RBL 9 OTBD FLOORBEAM ANGLE AT 280.00 CRACKED. FABRICATED NEW ANGLES AS REQUIRED IAW REO 690-53-21-478.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RBL 9 OTBD FLOORBEAM ANGLE AT 280.00 CRACKED. FABRICATED NEW ANGLES AS REQUIRED IAW REO 690-53-21-478.