What was found
AFTER TAKEOFF, HEARD A LOUD HISSING NOISE FROM MCD. CABIN RATE OF CLIMB WAS ZERO, DIFFERENTIAL PRESSURE WAS 5.2, CABIN ALT WAS 1600, LDG ELEVATION 1600 DURING CLIMB, LEVELED OFF AT 14,000' & RETURNED TO MSP FA REPORTED ALL MARKINGS GREEN & LOCKED. FOUND DAMAGE TO TO PAX DOOR SEAL STRIKER, REPAIRED SEAL STRIKER. R & R STRAP IAW REO 601R-53-22-033 TYPE IV, LEAK CHECK GOOD. OPERATIONS CHECKED GOOD IAW 52-11-10.