MAINTENANCE FOUND THE UPPER FLANGE OF THE FLOOR BEAM AT FS 349 TO BE CORRODED FROM RBL 33.20 TO RBL 42.50. THE CORROSION MEASURES 4.25 INCHES X 1.00 INCH X .034 INCH DEEP. REPAIRED IAW EA CRJ253-02335 & ASSOCIATED 8110-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAINTENANCE FOUND THE UPPER FLANGE OF THE FLOOR BEAM AT FS 349 TO BE CORRODED FROM RBL 33.20 TO RBL 42.50. THE CORROSION MEASURES 4.25 INCHES X 1.00 INCH X .034 INCH DEEP. REPAIRED IAW EA CRJ253-02335 & ASSOCIATED 8110-3.