What was found
LEFT OTBD FLAP AFT HINGE LUG FITTING AT FLS234.25 GOUGED & HAS OVERSIZED HOLES, OTBD LUG 0.4680 WITH REMAINING THICKNESS 0.218 INCHES, INBD LUG 0.4540 WITH REMAINING THICKNESS 0.203 INCHES. REPAIRED IAW REO 601R-57-53-1001.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT OTBD FLAP AFT HINGE LUG FITTING AT FLS234.25 GOUGED & HAS OVERSIZED HOLES, OTBD LUG 0.4680 WITH REMAINING THICKNESS 0.218 INCHES, INBD LUG 0.4540 WITH REMAINING THICKNESS 0.203 INCHES. REPAIRED IAW REO 601R-57-53-1001.