What was found
TASK CARD 900-53-140-509 FLIGHT ATTENDANT STATION G1 & G2 EMER EXIT FLOOR LEVEL LIGHTS INOPERATIVE 15. DURING TROUBLE SHOOTING FOUND FUSE F3 ON EMER BATTERY CHARGER FAILED. REPLACED FUSE IAW CMM RE 25-60-03. REMOVED & REINSTALLED EMER BATTERY CHARGER NR 1 IAW AMM 33-51-17-000-802-A02 & 33-51-17-400-802-A02. REMOVED & REINSTALLED BATTERY PACK IAW 33-51-17-000-801-A02 & 33-51-17-400-801-A02. OPERATIONS CHECKED EPSU GOOD IAW 33-51-17-710-801-A02.