Service difficulty report · Apu · Cndair CL6002B19

Difficulty date
February 23, 2015
Submitted
March 13, 2015
Operation
Air carrier
Aircraft
N8847A
Make and model
Cndair CL6002B19
Aircraft serial
7847
Aircraft time
24,577 hours, 21,776 cycles
Part
Apu
Condition
Malfunctioned
Location
Apu Bay
Stage of operation
CL
How discovered
O
Nature of condition
B, J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BURNING SMELL DURING CLIMB. WIP ON DM 000659 APU AUTO SHUT DOWN. WIP ON WORK SCOPE SMOKE & FUMES IN CABIN & COCKPIT IAW AML 3185062. INSP BLEED DUCT & CHECK VLV OFF APU IAW IPC 36-11-10 FIG ITEM 225A SPECIALLY THE INNER DIAMETER IAW MOTR RD IAW AML 3185065. APU GEN NEEDS TO BE REPLACED DUE TO APU REPLACEMENT. LT & RT COALESCER SOCKS REQUIRE REPLACEMENT DUE TO SMOKE SMELL IN CABIN IAW AML 3185065. FOR CORRECTIVE ACTION SEE AML PG 3185064 NR 2 PERFORMED WORK SCOPE FOR FUMES & SMOKE IN CABIN & FLIGHT DECK, SMOKE TOILET MSG 200 IAW GMM PROCEDURES & ALSO SEE AML PG 3185064 NR 1 FOR REPLACEMENT OF APU IAW APU CHANGE CHECKLIST. R & R APU IAW APU CHANGE CHECKLIST APU TOTAL HRS 15014, TOTAL CYCLES 30949 SN P-1191 THIS CLEARS DM 000659 PLACARD REMOVED MM02 UPDATED. INFO ONLY COMPLETED WORK SCOPE FOR SMOKE & FUMES IN CABIN & FLIGHT DECK & SMOKE TOILET MSG 200 IAW GMM PROCEDURES. REMOVED BLEED DUCT BETWEEN APU LCV & CONNECTION AT ISOLATION VLV, INSPECTED FOR OIL CONTAMINATION, NONE FOUND. REINSTALLED DUCT IAW AMM 36-11-35. R & R APU GEN IAW AMM 24-22-01-400-801. R & R LT & RT COALESCER SOCKS IAW AMM 21-51-13.