What was found
BURNING SMELL DURING CLIMB. WIP ON DM 000659 APU AUTO SHUT DOWN. WIP ON WORK SCOPE SMOKE & FUMES IN CABIN & COCKPIT IAW AML 3185062. INSP BLEED DUCT & CHECK VLV OFF APU IAW IPC 36-11-10 FIG ITEM 225A SPECIALLY THE INNER DIAMETER IAW MOTR RD IAW AML 3185065. APU GEN NEEDS TO BE REPLACED DUE TO APU REPLACEMENT. LT & RT COALESCER SOCKS REQUIRE REPLACEMENT DUE TO SMOKE SMELL IN CABIN IAW AML 3185065. FOR CORRECTIVE ACTION SEE AML PG 3185064 NR 2 PERFORMED WORK SCOPE FOR FUMES & SMOKE IN CABIN & FLIGHT DECK, SMOKE TOILET MSG 200 IAW GMM PROCEDURES & ALSO SEE AML PG 3185064 NR 1 FOR REPLACEMENT OF APU IAW APU CHANGE CHECKLIST. R & R APU IAW APU CHANGE CHECKLIST APU TOTAL HRS 15014, TOTAL CYCLES 30949 SN P-1191 THIS CLEARS DM 000659 PLACARD REMOVED MM02 UPDATED. INFO ONLY COMPLETED WORK SCOPE FOR SMOKE & FUMES IN CABIN & FLIGHT DECK & SMOKE TOILET MSG 200 IAW GMM PROCEDURES. REMOVED BLEED DUCT BETWEEN APU LCV & CONNECTION AT ISOLATION VLV, INSPECTED FOR OIL CONTAMINATION, NONE FOUND. REINSTALLED DUCT IAW AMM 36-11-35. R & R APU GEN IAW AMM 24-22-01-400-801. R & R LT & RT COALESCER SOCKS IAW AMM 21-51-13.