Service difficulty report · Bpsu · Cndair CL6002B19

Difficulty date
April 6, 2015
Submitted
April 9, 2015
Operation
Air carrier
Aircraft
N8980A
Make and model
Cndair CL6002B19
Aircraft serial
7980
Aircraft time
22,171 hours, 19,609 cycles
Part
Bpsu
Condition
Malfunctioned
Location
Te Flap
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLAPS FAIL CAUTION CAME ON DURING CRUISE, 20 MIN INTO FLIGHT, -40C, 0 FLAP INDICATION, 295 KTS, FLAPS STOPPED, CLEAR SKY. FROM MM02 MEL CONTROL 001050 FLAP FAIL CAUTION. RESET FLAP SYS UNDER MOC DIRECTION IAW FIM, RESET PROCEDURES, MSG NO LONGER REMAINS, CYCLED FLAPS 5 TIMES & PROBLEM DID NOT REOCCUR. DEFERRED FLAP SYS IAW MEL 27-50-00 CAT A UNDER DIRECTION OF MOC TC 4488. ENTERED ITEM IN MM02 PLACARD INSTALLED. PERFORMED TROUBLESHOOTING IAW FIM REV 48 IAW AD 2009-06-12 PARAGRAPH H 6 I, AMOC LOG 14-105 DATED 12 30 2014. INTERROGATED FECU FOR FAULT HISTORY, WHICH FLAGGED THE RT BPSU. PERFORMED CHECK OF WIRING HARNESS TO RT BPSU, NO DEFECTS NOTED IAW FIM 27-50-00. REPLACED RT BPSU IAW AMM 27-51-10. PN OFF 855D100-11, PN ON 855D100-15, SN OFF 2291 & SN ON1965. OPERATIONS CHECKED GOOD AT THIS TIME.