What was found
INTERMITTENT FIRE SYS FAULT STATUS MESSAGE INFLT. WOULD COME ON FOR 5-10 SECONDS EVERY MINUTE OR 2. STOPPED AFTER DESCENDING OUT OF FL360. NO CODE LOGGED IN MDC. R & R HARNESS FIRE SENSOR IAW AMM 26-11-09, NO FIX. DM REMAINS OPEN 31739 89-1. R & R LOWER, UPPER & SIDE FIRE DETECTION LT ENG LOOPS A234, A235, A236 & IAW AMM 26-11-03, 26-11-01, 26-11-05 & 26-10-01. OPERATIONS CHECKED GOOD IAW AMM 26-10-00.