What was found
ELECTRICAL BURNT & SHORT SMELL COMING FROM CAPTAINS SIDE WINDSHIELD HEATING MODULE ELEMENT ONLY OCCURRED ON LAST FLIGHT. PERFORMED VISUAL INSPECTION OF WIRES AROUND TERMINAL BLOCK ON THE CAPTAINS SIDE WINDSHIELD, NO SIGN OF BURNING OR ARCING WIRES. PERFORMED OPERATIONS CHECK OF WINDSHIELD HEAT WITH TASKS IN AMM 56-11-01. PERFORMED OPERATIONS CHECK OF MAP LIGHT IAW AMM 33-13-07 & TASK 33-13-00-710-801. OPERATIONS CHECK OF FLOOD LIGHTS IAW AMM 33-13-01 & TASK 33-13-00-710-801. ALL OPERATIONS CHECKED GOOD.