What was found
PASSENGER COMPARTMENT UNDER FLOORBOARD, BETWEEN FS 310 - 333.00 AT STRINGER 20L LOCATION, THERE ARE 2 EACH INTERCOSTALS CORRODED. R & R INTERCOSTAL, PN 670-31823-1, BETWEEN FS 310 - 333 IAW SRM 51-42-06-001-001-A01, 51-40-14-001-001-A01 & 51-42-21-001-001-A01. REFER TO CO 15163115 JOB 81516311 OP 70 FOR DETAILS OF WORK PERFORMED.