What was found
PASSENGER COMPARTMENT UNDER FLOORBOARDS, BETWEEN FS 310.00 - 319.70 AT STRINGER 20R LOCATION, THE INTERCOSTAL IS CORRODED. R & R INTERCOSTAL, PN SH670-32047-1, AT STRINGER 20R, FS 310 - 319.70 IAW SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01 & 51-42-21-001-001-A01. REFERENCE CO 15163115 JOB 81516311 OP 71 FOR DETAILS OF WORK PERFORMED.