What was found
GEAR DISAGREE ON TAKEOFF. NOSE GEAR REMAINED IN DOWN POSITION. RAN QRH & DID NOT FIX ISSUE. NOSE DOOR MSG ALSO DISPLAYED. DEFERRED LG RETRACTION SYS IAW MEL 32-30-01. ALL MX REQUIREMENT COMPLIED WITH. PLACARDED IAW MEL, ENTERED INTO MM02. ACFT OK FOR SERVICE. FOUND BRACKET BENT OUT OF POSITION & WOW 2 & CTR HARNESS CRUSHED NEAR AT WOW 2 PROX SENSOR. R & R HARNESS IAW AMM 32-61-25. R & R SENSOR BRACKET & UPPER TORQUE LINK TARGET IAW CMM 32-20-04. ADJUSTED & TESTED IAW AMM 32-61-00. EXTENSION & RETRACTION OPERATIONS CHECKED GOOD. THIS CLEARS DM OO2624. PLACARD REMOVED, PSEU MEMORY CLEARED & MMO2 CLEARED.