What was found
RIGHT FWD FUSELAGE POWER RECEPTACLE STRUCTURE CRACKED. REMOVED ACFT POWER RECEPTACLE BRACKET IAW SRM 51-42-06 & SRM 51-42-21. INSTALLED ACFT POWER RECEPTACLE BRACKET IAW SRM 51-42-06 & 54-42-21. LOCATED & DRILLED NEW AC POWER BRACKET RECEPTACLE IAW SRM 51-40-11. REMOVED AC POWER RECEPTACLE IAW AMM 24-41-03-000-802. INSTALLED SAME SERVICEABLE EXTERNAL AC POWER RECEPTACLE IAW AMM 24-41-03-400-802,. REMOVED EXTERNAL SERVICE PANEL BY REMOVING 4 SCREWS IAW SRM 51-41-02. INSTALLED EXTERNAL SERVICE PANEL BY INSTALLING 4 SCREWS IAW SRM 51-41-02. CLOSE OUT STEPS 4A & B OF AMM 24-41-03-400-802 REQUIRE COMPLETION. COMPLIED WITH CLOSEOUT STEPS 4A & B OF AMM 24-41-03-400-802. NO DEFECTS NOTED. R & R AC POWER RECEPTACLE BRACKET PN 600-33283-33 IAW SRM 51-42-06 & 51-42-21.