What was found
FS 333.00 FRAME CRACKED APPROX 2""L AT STRINGER 1L. R & R CRACKED FRAME AT FS 333, BETWEEN STRINGER 0 & STRINGER 3L IAW SRM 61-42-06 & 51-12-21. REMOVED CRACKED FRAME AT FS 333, BETWEEN STRINGER 0 & 3L IAW SRM CH 51-42-06 & SRM CH 51-42-21. REPLACE FRAME PN 601R32004-41 IAW SRM 51-42-06 & SRM 51-42-21. LOCATED & DRILLED NEW FRAME PN 601R32004-41 IAW SRM 51-40-11. BONDING WIRE N103 ON FS 333 FRAME REQUIRES INSTALLATION. UPON FURTHER INVESTIGATION, FOUND NO GND WIRES REQUIRING ATTACHMENT TO GND STUD N103 IAW WM 91EEL & 91EWL. GND STUD N103 IS INSTALLED AT FS 333, BETWEEN STRINGER 0 & 3L.