What was found
EMERGENCY LIGHTS LOCATED BEHIND PANELS 171CL & 172CR HAVE BROKEN GROUND WIRES. REPAIRED GND WIRES FOR EMER LIGHTS IAW ESPM 20-16-05. BOND TEST GOOD IAW AMM 51-80-00-760-801-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHTS LOCATED BEHIND PANELS 171CL & 172CR HAVE BROKEN GROUND WIRES. REPAIRED GND WIRES FOR EMER LIGHTS IAW ESPM 20-16-05. BOND TEST GOOD IAW AMM 51-80-00-760-801-A01.