What was found
FS 280, FWD J ANGLE IS CORRODED AROUND FASTENER HOLES. LOCATED, DRILLED & INSTALLED NEW FS 280 FWD J ANGLE IN PLACE OF DAMAGED FWD J ANGLE PN 600-34017-351 IAW 51-40-11, 51-42-06 & 51-42-21
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 280, FWD J ANGLE IS CORRODED AROUND FASTENER HOLES. LOCATED, DRILLED & INSTALLED NEW FS 280 FWD J ANGLE IN PLACE OF DAMAGED FWD J ANGLE PN 600-34017-351 IAW 51-40-11, 51-42-06 & 51-42-21