What was found
SERVICE DOOR FLOOR SILL IS CORRODED, BETWEEN FS 319 - 349. CONTINUATION CARD 167. R & R SERVICE DOOR LOWER SILL ANGLE IAW SRM 51-42-21, 51-42-06, 51-42-10, 51-42-21 & 51-42-36. SEE JC 8794311 OP 129 FOR STEPS 1 - 5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SERVICE DOOR FLOOR SILL IS CORRODED, BETWEEN FS 319 - 349. CONTINUATION CARD 167. R & R SERVICE DOOR LOWER SILL ANGLE IAW SRM 51-42-21, 51-42-06, 51-42-10, 51-42-21 & 51-42-36. SEE JC 8794311 OP 129 FOR STEPS 1 - 5.