What was found
PRESSURE BULKHEAD AT FS 621 - 625.3, AT STRINGER 13L & 14L, HAS CRACKED INTERCOSTAL CLIPS, INSPECTED IAW REO 601R-53-61-5230 & IS DUE RE-INSPECT OF BULKHEAD CAP ANGLE & INTERCOSTAL CLIPS AT INTERVALS NOT TO EXCEED 1200 FH & TO BE REPAIRED AT OR BEFORE 5000 FH. CONTINUATION CARD 8798016 OP 9. REPLACED INTERCOSTAL CLIPS IAW SRM 51-42-21 & 51-42-06. REFERENCE MWC JOB 8798016 OPERATIONS 6 & 9 FOR WORK PERFORMED.