What was found
PAX CABIN, GUSSET CHAFED FWD OF SERVICE DOOR CUTOUT AT S-10R. BLENDED AREA IAW SRM 51-12-00, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00, FABRICATED NEW GUSSET IAW SRM 51-24-16, LOCATED AND DRILLED IAW SRM 51-40-11, FINISH COAT IAW SRM 53-21-23, INSTALLED NEW PART IAW SRM 51-42-20.