What was found
LT WING, INBD LE AILERON PANEL HAS CHAFE DAMAGE, APPROX 1"" X 3"" & 0.015"" DEEP. ADJACENT TO FASTENER HOLE. DRILLED & LOCATED HOLES FOR NEW PANEL 599AB IAW SRM 51-40-11-001-001-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT WING, INBD LE AILERON PANEL HAS CHAFE DAMAGE, APPROX 1"" X 3"" & 0.015"" DEEP. ADJACENT TO FASTENER HOLE. DRILLED & LOCATED HOLES FOR NEW PANEL 599AB IAW SRM 51-40-11-001-001-A01.